Figure 9. Alarm Management Settings
3. Set the alarm input type to be Normally Opened (N.O) or Normally Closed (N.C).
4. Check the checkbox next to Setting and click the Handle button to enter the Alarm Input Handle menu.
5. Select the Triggered Camera tab.
6. Select cameras to trigger for recording when alarm occurs by checking the checkboxes under the
desired cameras, as shown in Figure 10.
Figure 10. Triggered Camera Menu
7. User may select the PTZ camera to link with the alarm input and then set the callup of preset, patrol and
pattern for alarm linked actions.
8. Click the OK button to complete setup.
You may now add a schedule to start recording when an alarm is triggered (See Scheduling a Recording).
Alarm outputs may also be configured in the Alarm Management menu. To set up Alarm Output:
1. Select the Alarm Output tab. This will bring up the Alarm Output interface, shown in Figure 11.